Hi, thank you for the reply.
I think I found the issue: I was taking account of the FIFO roll over only when I was updating REG_CMD_WRITE at the end of the display list, but not when I was sending the memory address at the beginning of each data bursts.
After doing the correction now it seems to work perfectly.
Thank you for the support, going deep in your suggest to report the FIFO counter handling let me understood the problem!
Regards,
Marco.
I think I found the issue: I was taking account of the FIFO roll over only when I was updating REG_CMD_WRITE at the end of the display list, but not when I was sending the memory address at the beginning of each data bursts.
After doing the correction now it seems to work perfectly.
Thank you for the support, going deep in your suggest to report the FIFO counter handling let me understood the problem!
Regards,
Marco.